<?xml version="1.0" encoding="utf-8"?>
<!-- generator="FeedCreator 1.7.2-ppt DokuWiki" -->
<?xml-stylesheet href="http://cso.caltech.edu/wiki/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="http://cso.caltech.edu/wiki/feed.php">
        <title>CSO Wiki cso:safety</title>
        <description></description>
        <link>http://cso.caltech.edu/wiki/</link>
        <image rdf:resource="http://cso.caltech.edu/wiki/lib/tpl/cso/images/favicon.ico" />
       <dc:date>2026-09-17T21:44:46+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/badweather?rev=1429834694&amp;do=diff"/>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/hot_work?rev=1296442952&amp;do=diff"/>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/lifting?rev=1296444056&amp;do=diff"/>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/lockout?rev=1296443689&amp;do=diff"/>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/power_fail?rev=1385088985&amp;do=diff"/>
                <rdf:li rdf:resource="http://cso.caltech.edu/wiki/cso/safety/safety?rev=1402602142&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="http://cso.caltech.edu/wiki/lib/tpl/cso/images/favicon.ico">
        <title>CSO Wiki</title>
        <link>http://cso.caltech.edu/wiki/</link>
        <url>http://cso.caltech.edu/wiki/lib/tpl/cso/images/favicon.ico</url>
    </image>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/badweather?rev=1429834694&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2015-04-24T00:18:14+00:00</dc:date>
        <title>Adverse Weather</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/badweather?rev=1429834694&amp;do=diff</link>
        <description>Adverse Weather

Observing

Stay aware of the weather conditions while observing.
Look outside occasionally. There are many weather resources available, including the EAO weather summary.

In case of adverse weather, close the shutter immediately. Remember it takes quite a long time (15 min) to close the shutter completely.</description>
    </item>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/hot_work?rev=1296442952&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2011-01-31T03:02:32+00:00</dc:date>
        <title>Hot Work Procedure</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/hot_work?rev=1296442952&amp;do=diff</link>
        <description>Hot Work Procedure

Scope

Contractors and Maintenance projects being performed at the CSO Base Facility or at the Summit site. 

Responsible Party

Contractors or Maintenance Personnel performing Hot Work. 

Technical Manager or Day Crew Leader

Will issue hot work permits to responsible parties.</description>
    </item>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/lifting?rev=1296444056&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2011-01-31T03:20:56+00:00</dc:date>
        <title>Common lifting protocol</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/lifting?rev=1296444056&amp;do=diff</link>
        <description>Common lifting protocol

All lifting and instrument changes should be done with a minimum of two people. Three people are helpful in some instances. Crane operator should turn off distracting music or other noise, and attempt to move control pendant as close to lifting job as is reasonable. The man at the load should be giving clear directions to the crane operator in a loud voice preferably using the appropriate universal hand signals simultaneously. Crane operator should not move load unless d…</description>
    </item>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/lockout?rev=1296443689&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2011-01-31T03:14:49+00:00</dc:date>
        <title>Lockout/Tagout Procedures</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/lockout?rev=1296443689&amp;do=diff</link>
        <description>Lockout/Tagout Procedures

General Lockout/Tagout Procedures

Telescope Tagout

Prior to working on the telescope or on/under the dome, and the machinery must not be moved, please press the red button in the control room and hang a “lockout” tag on the control room red button. An official looking</description>
    </item>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/power_fail?rev=1385088985&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2013-11-22T02:56:25+00:00</dc:date>
        <title>Power Failure Response</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/power_fail?rev=1385088985&amp;do=diff</link>
        <description>Power Failure Response

If there is a power failure, start the emergency generator. This provides power to close the shutter, which is the first priority. The generator will also keep the UPSs and the cryogenic compressors running, but nothing else in the dome.</description>
    </item>
    <item rdf:about="http://cso.caltech.edu/wiki/cso/safety/safety?rev=1402602142&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2014-06-12T19:42:22+00:00</dc:date>
        <title>Safety Information</title>
        <link>http://cso.caltech.edu/wiki/cso/safety/safety?rev=1402602142&amp;do=diff</link>
        <description>Safety Information

Please familiarize yourself with this material before going to the telescope (summit) for the first time and at least annually thereafter. Additonal information may be found in the hardcopy CSO Safety Notebook. 
Copies are available at the summit and HP sites.</description>